Ye Tian, Yongwan Lim, Ziwei Zhao, Dani Byrd, Shrikanth Narayanan, and Krishna S. Nayak. Aliasing Artifact Reduction in Spiral Real-Time MRI. Magnetic Resonance in Medicine, 2021.

Download

[HTML] 

Abstract

Purpose To mitigate a common artifact in spiral real-time MRI, caused by aliasing of signal outside the desired FOV. This artifact frequently occurs in midsagittal speech real-time MRI. Methods Simulations were performed to determine the likely origin of the artifact. Two methods to mitigate the artifact are proposed. The first approach, denoted as “large FOV” (LF), keeps an FOV that is large enough to include the artifact signal source during reconstruction. The second approach, denoted as “estimation-subtraction” (ES), estimates the artifact signal source before subtracting a synthetic signal representing that source in multicoil k-space raw data. Twenty-five midsagittal speech-production real-time MRI data sets were used to evaluate both of the proposed methods. Reconstructions without and with corrections were evaluated by two expert readers using a 5-level Likert scale assessing artifact severity. Reconstruction time was also compared. Results The origin of the artifact was found to be a combination of gradient nonlinearity and imperfect anti-aliasing in spiral sampling. The LF and ES methods were both able to substantially reduce the artifact, with an averaged qualitative score improvement of 1.25 and 1.35 Likert levels for LF correction and ES correction, respectively. Average reconstruction time without correction, with LF correction, and with ES correction were 160.69 ± 1.56, 526.43 ± 5.17, and 171.47 ± 1.71 ms/frame. Conclusion Both proposed methods were able to reduce the spiral aliasing artifacts, with the ES-reduction method being more effective and more time efficient.

BibTeX Entry

@article{Tian2021AliasingArtifactReductionin,
 author = {Tian, Ye and Lim, Yongwan and Zhao, Ziwei and Byrd, Dani and Narayanan, Shrikanth and Nayak, Krishna S. },
 bib2html_rescat = {span},
 journal = {Magnetic Resonance in Medicine},
 title = {Aliasing Artifact Reduction in Spiral Real-Time MRI},
doi = {https://doi.org/10.1002/mrm.28746},
url = {https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.28746},
eprint = {https://onlinelibrary.wiley.com/doi/pdf/10.1002/mrm.28746},
abstract = {Purpose To mitigate a common artifact in spiral real-time MRI, caused by aliasing of signal outside the desired FOV. This artifact frequently occurs in midsagittal speech real-time MRI. Methods Simulations were performed to determine the likely origin of the artifact. Two methods to mitigate the artifact are proposed. The first approach, denoted as “large FOV” (LF), keeps an FOV that is large enough to include the artifact signal source during reconstruction. The second approach, denoted as “estimation-subtraction” (ES), estimates the artifact signal source before subtracting a synthetic signal representing that source in multicoil k-space raw data. Twenty-five midsagittal speech-production real-time MRI data sets were used to evaluate both of the proposed methods. Reconstructions without and with corrections were evaluated by two expert readers using a 5-level Likert scale assessing artifact severity. Reconstruction time was also compared. Results The origin of the artifact was found to be a combination of gradient nonlinearity and imperfect anti-aliasing in spiral sampling. The LF and ES methods were both able to substantially reduce the artifact, with an averaged qualitative score improvement of 1.25 and 1.35 Likert levels for LF correction and ES correction, respectively. Average reconstruction time without correction, with LF correction, and with ES correction were 160.69 ± 1.56, 526.43 ± 5.17, and 171.47 ± 1.71 ms/frame. Conclusion Both proposed methods were able to reduce the spiral aliasing artifacts, with the ES-reduction method being more effective and more time efficient.}
 year = {2021}
}

Generated by bib2html.pl (written by Patrick Riley ) on Fri Mar 22, 2024 09:15:40